Chapter 5 Modulated Waveform Output
DG4000 User's Guide
5-13
To Select the Modulating Waveform Source
Press
Mod
Source to select "Int" or "Ext" modulating waveform source.
1.
Internal Source
When internal source is selected, the modulating waveform is set as a Square
with 50% duty cycle, and the rate at which the output amplitude "shifts"
between "carrier amplitude" and "modulating amplitude" is determined by
"ASK Rate".
2.
External Source
When external source is selected, the generator receives the external
modulating signal from the
[Mod/FSK/Trig] connector at the rear panel.
Note: The
[Mod/FSK/Trig] connector is different when controlling ASK
and AM/FM/PM modulations externally. In ASK modulation, the
[Mod/FSK/Trig] connector has adjustable edge polarity.
To Set the ASK Rate
When internal source is selected, press
ASK Rate to set the rate at which the
output amplitude shifts between "carrier amplitude" and "modulating amplitude".
Use the numeric keyboard or direction keys and knob to input the desired
frequency value.
The frequency range is from 2mHz to 1MHz and the default is 100Hz.
Note: When "Ext" modulation source is selected, this menu would be grayed out
and disabled.
[Mod/FSK/Trig]
Summary of Contents for DG4062
Page 2: ......
Page 14: ...RIGOL XII DG4000 User s Guide...
Page 92: ......
Page 128: ......
Page 140: ......
Page 150: ......
Page 210: ......
Page 213: ...Chapter 11 Remote Control RIGOL DG4000 User s Guide 11 3 3 4 5 6...
Page 218: ......
Page 222: ......