E2-07: Charging for ? sec
Main Menu>Programming>ENT>Aux-Relay>ENT
z
This setting switches the Aux-Relay 1 OFF when the AC CHARGER started for a certain time
(E2-07). This can be useful when the Aux-Relay 1 is for instance used a low battery alarm.
z
Use the Set Udc Lower than ? Voltage (E1-03) setting to start the alarm and use this setting
(E2-07) to stop it.
※
Note: As along as the battery voltage is lower than the specified limit (E1-03), the alarm will be
active.
E2-08: Fan OFF for ? sec
Main Menu>Programming>ENT>Aux-Relay>ENT
z
This will switch the Aux-Relay 1 OFF when the internal fan switches off. This can be used
together with the E1-08: Fan ON for ? sec setting to drive an external fan.
E2-09: Charge finished for ? Min (When E2-09=0, ignore this setting)
Main Menu>Programming>ENT>Aux-Relay>ENT
z
This condition becomes active when the charge bulk phase is finished for a certain time
(E2-09).
z
For the charge curve, take a look at for instance the Charge Current (D1-08) setting.
z
This is useful when the Aux-Relay 1 is used to start a generator. Once started, one might want to
keep the generator on until the batteries are more or less charged.
E2-10: Aux-Relay 1 not ON for ? minutes (When E2-10=0, ignore this setting)
Main Menu>Programming>ENT>Aux-Relay>ENT
z
If one does not need special off condition, one can use this setting and the Aux-Relay 1 will
switch off automatically when there has been no ON condition for a certain time (E2-10).
E2-11: AC IN loss for ? sec (When E2-11=0, ignore this setting)
Main Menu>Programming>ENT>Aux-Relay>ENT
z
This setting will switch off Aux-Relay1 if the RMS value of AC IN voltage is too low for a
certain time (E2-11).
z
This AC level is determined by the AC IN Low Disconnect (B2-01) setting.
z
Use this setting (E2-11) to disable re-starting of a generator which is switched off by hand when
the Aux-Relay 1 is used to generate a start signal for that generator.
Summary of Contents for Invertek CombiPlus
Page 1: ......
Page 2: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 2...
Page 8: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 8 Layout...
Page 109: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 109 Chapter 8 Constants list...
Page 128: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 128 NOTES...