‘ ’: blink
The charging time of AC
CHARGER has been over
10 hours and remains in
Bulk Charge mode.
(D1-09=1) shows the battery
is at fault.
Replace the battery banks.
The AC IN voltage or
frequency is out of range.
Ensure that the AC IN
voltage is within the range
220V system:
180VAC~260VAC
110V system:
90VAC~130VAC
And that the frequency
matches the setting.
The charger is not
functioning
“CombiPlus®” internal
circuit breaker has tripped.
Reset the internal circuit
breaker.
Incorrect charging current.
Set the charging current at
between (0.1~0.2)
×
battery
capacity.
A defective battery
connection.
Check the battery terminals.
The absorption voltage has
been set to an incorrect
value.
Adjust the absorption
voltage to the correct value.
The float voltage has been
set to an incorrect value.
Adjust the float voltage to
the correct value.
The battery is not being
charged fully.
The internal DC fuse is
defective
“CombiPlus®” will need to
be set to service for repair.
‘Bat-NG’
Battery Fault
Bat-NG
Battery Fault
Summary of Contents for Invertek CombiPlus
Page 1: ......
Page 2: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 2...
Page 8: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 8 Layout...
Page 109: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 109 Chapter 8 Constants list...
Page 128: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 128 NOTES...