Rich Electric Co. “CombiPlus” User Manual V7.19 Copyright 2009
Page 45
O2-07: RUN/STOP Key Hold Time
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
Use constant O2-07 to set the time it takes to press RUN/STOP key to activate its
function.
z
Initial setting=2 sec, setting range: 2~10 sec.
O2-08: Power ON Auto Run Select
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
Use constant O2-08 to select to auto run manually or automatically.
Setting Function
O2-08=0
Auto Run is active when pressing Run/STOP key
O2-08=1
(Initial setting)
Auto Run is active when the power is on.
O2-09: LCD Display Idle Time Set
Main Menu>Programming>ENT>Operator>ENT>Key Selections>ENT>
z
When O2-09=0, Display Idle Function is disabled.
z
Use constant O2-09 to set the idle time when the keypad is not operated and all the
LCD Display and LED Indicators of the CombiPlus® entering the idle mode which
only RUN/STOP indicator is active.
z
Once any key on the panel is pressed, it will return to the display before Idle status.
z
Initial setting=10 min, setting range: 0~60 min.
Summary of Contents for Invertek CombiPlus
Page 1: ......
Page 2: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 2...
Page 8: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 8 Layout...
Page 109: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 109 Chapter 8 Constants list...
Page 128: ...Rich Electric Co CombiPlus User Manual V7 19 Copyright 2009 Page 128 NOTES...