52
SCT-1100 Weight Transmitter
PC Serial
Transmission on the PC Serial – In the secondary mode, this step is not displayed if the
functioning mode
has been set in the
step; if the
mode has been set, only the
,
,
,
and
parameters are displayed.
Transmission on external command (PC or PLC)
Transmission to 4 digit remote display
Transmission to 6 digit remote display / Reception of the “rEPE.6” string
Transmission of standard string by pressing
.
displays to confirm transmission
Transmission of extended string by pressing
.
displays to confirm transmission
NOTE: If the TOTALIZER mode (horizontal or vertical) is active, the transmission is carried
out by pressing
Transmission with RS-485 protocol; selection of this parameter
displays momentarily, enter
the address of the unit (0 to 98), then prompts to enter baud rate and bit display
Transmission with the MODBUS protocol; selection of this parameter
displays, select
; then
displays, enter the address of the unit (0 to 98); then prompts to enter
baud rate and bit display
Fieldbus type; selections are
,
,
,
,
,
Continuous transmission of standard string; selection of this parameter prompts to enter baud
rate and bit display
Continuous transmission of extended string (or multi-scale string in the
mode); selection
of this parameter prompts to enter baud rate and bit display
Selection of this parameter prompts to enter baud rate and bit display
Transmission of each weigh with standard string: selection of this parameter prompts to enter
baud rate and bit display
Transmission of each weigh with extended string (or multi-scale string in the
mode);
selection of this parameter prompts to enter baud rate and bit display
Transmission protocol that sends only a portion of the weight, for example only the tare weight by
setting different parameters:
this parameter displays only if
is selecte
d in the secondary
mode
Transmission protocol that allows management of the received string without setting any parame-
ters: the parameter displays only if
functioning mode is selected in the secondary mode
Transmission protocol that allows an ASCII string to be received; both numbers and letters can be
displayed; the parameter displays only if
functioning mode is selected in the secondary
mode
Transmission protocol that allows for reception of a string from a remote scale. The parameter
displays only if the
functioning mode is selected in the secondary mode.
When this protocol is selected, the following parameters for the management of the remote scale
must also be set:
•
– Remote scale terminator: Enter the decimal ASCII code (up to 2 characters) of the
terminator characters of the weight string (e.g. 13 for CR or 10 for LF).
•
– Remote scale weight position: Set the position of the first character of the weight
value, in the string transmitted by the remote scale. The first character on the left of the string
has the 00 position. A possible character sign is also part of the weight value.
For example, if the received string is:
In this example, set the 00 value; It is possible to set up to 2 characters (from 00 to 39); Default 00
•
– Length of the weight data string: Enter the number of digits which make up the
weight value (01 to 39); include the sign and the weight digits. For example, if the transmitted
string sppp CR + LF, in which s is the weight sign, ppppppp is the weight value, uu
is the unit of measure, the length of the weight string has a value of 08. Default is 01
Parameter
Settings
Description
Table 6-2. Serial Menu Parameters and Settings (Continued)
Received String
s
p
p
p
p
p
p
p
u
u
CR
LF
Character Position
00
01
02
03
04
05
06
07
08
09
10
11