66
SCT-1100 Weight Transmitter
Extended String
Extended string transmitted on the print port when
=
or
C, SS,NT,WWWWWWWW,UU<CR LF>
In which:
C
Secondary or sum:S, if the sum is sent;
Secondary number, if 1 salve weight is sent
SS
Status (see standard string)
WWWWWWWW
weight
UU
unit of measure
<CR LF>
Carriage Line Feed (ASCII decimal character 13 and 10).
In
mode, when
is selected the weight value is always zero.
When the
=
is set, only the weight is transmitted on the printer port.
6.6
Remote Scale Configuration
This section describes how to set the remote scale string parameters.
Take the string:
REXT<CR>1,ST,_____6.000,PT_____0.000,_________0,kg<CR><LF>
Where:
<CR> = ASCII 013
<LF> = ASCII 010
1. Insert every character into the table below:
Where:
Is the weight
Is the tare type
Is the tare weight
Is the character terminator. It is recommended the character terminator is unique and the last character of the string.
0 1 2 3 4 5 6 7 8 9 10111213141516171819202122232425262728293031323334353637383940414243444546 47 48
R E X T CR 1 , S T , _ _ _ _ _ 6 . 0 0 0 , P T _ _ _ _ _ 0 . 0 0 0 , _ _ _ _ _ _ _ _ _ 0 , k g CR LF
W W W W W W W W W W
M M T T T T T T T T T T
E
W W W W W W W W W W
M M
T T T T T T T T T T
E
Note