Operation
29
Press :
• cancels the previously set reference;
momentarily displays (if there is not a valid reference, the
message does not display)
• After canceling a reference press
to set a new reference value
Operation
Use a reference quantity equal to or greater than 0.1% of the scale capacity. The weight of the reference quantity
should not create an APW lower than the two internal points of the converter (intrinsic limit of the scale). If this
condition occurs, during the sampling
momentarily displays and the quantity put on the scale is not
accepted. Repeat using a higher reference quantity.
1. Place an empty container on the scale and press
to tare it.
2. Ensure the weight display is zero, then press
. A prompt for a reference quantity displays.
3. Press
or
until the desired value displays (
,
,
,
,
,
,
,
,
,
).
4. Place the quantity of pieces selected in
on the scale. Press
to confirm.
displays and the
instrument calculates the APW. After a few seconds, the quantity of pieces put on the platform displays
and should equal the value selected in
5. Add the rest of the items to count into the container. The count value displays.
6. Unload the scale.
displays.
The APW remains stored until the instrument is turned off, allowing for the counting of similar pieces, without
having to repeat the REFERENCE operation.
Pressing
toggles the display between the number of pieces and the net weight.
To perform a new reference operation:
1. Press when the number of pieces displays.
displays to confirm the cancellation of the reference
value.
2. Press
to set a new REFERENCE value and repeat operations starting with
I
f the number of calculated pieces is greater than
, only the first 6 digits are displayed.
Switching from 1 channel to another does not cancel the reference and the currently selected mode (weight or
pieces) remains and can be toggled by pressing
.
Piece Counting When Picking
1. Place a full container on the scale and press
to tare it.
2. Ensure the weight display is zero, then press
. A prompt for a reference quantity displays.
3. Press
or
until the desired quantity to remove displays. (
,
,
,
,
,
,
,
,
,
).
4. Remove the quantity of pieces selected in
from the scale.
5. Press
to
confirm.
displays and the instrument calculates the APW. The removed quantity
displays.
6. Continue the counting in extraction.
If during the sampling phase the weight is unstable and it is not possible to calculate the APW correctly,
displays momentarily. Repeat the sampling operation.
C
Note
C
Note
Note