64
SCT-1100 Weight Transmitter
6.5.2
Extended String
Without APW (any mode other than counting or in response to the REXT command):
[CC]B,hh,NNNNNNNNNN,YYTTTTTTTTTT,PPPPPPPPPP,uu,(dd/mm/yybbhh:mm:ss|NO DATE TIME)<CR
LF>
With APW (in piece counting mode or in response to the REXT command
)
:
[CC]B,hh,NNNNNNNNNN,YYTTTTTTTTTT,PPPPPPPPPP,AAAA.AAAAA,uu<CR LF>
In which:
[CC]
is the instrument code as two ASCII decimal digits (RS-485 protocol)
B
scale number (1 in a scale with equalized channel mode (DEP.CH)
the channel number from 1–4 in scale with independent channels mode (IND.CH).
,
Comma character
hh
UL
Under load
OL
Overload
ST
Stability of display
US
Instability of display
,
Comma character
NNNNNNNNNN
Net weight on 10 characters including possible sign and decimal point
,
Comma character
YY
PT if the tare is manual, if YY = two empty spaces display with semiautomatic tare
,
Comma character
TTTTTTTTTT
Tare weight on 10 characters including possible sign and decimal point
,
Comma character
PPPPPPPPPP
Number of pieces on 10 characters, equal to 0 if the instrument is in a functioning mode other
than the counting mode
,
Comma character
AAAA.AAAAA
Average Piece Weight on 10 characters with 5 decimals. The Average Piece Weight is always
reported in grams.
,
Comma character
uu
Unit of measure Kg,
b
g,
b
t, lb; (
b
signifies blank)
,
Comma character (only with REXD command)
dd/mm/yy
Date in the dd/mm/yy format (only with REXD command)
bb
2 space characters, ASCII decimal 32 character (only with REXD command)
hh:mm:ss
Time format (only with REXD command)
CR
Carriage Return (ASCII decimal 13 character)
LF
Line Feed (ASCII decimal 10 character)
The non significant digits of the net, tare, pieces and gross weights are filled with spaces (space characters, ASCII
decimal 32 character).
If the optional TIME DATE board has not been detected, in response to the REXD command, only the weight is