CHAPTER 28 ELECTRICAL SPECIFICATIONS
User’s Manual U19780EJ2V0UD
637
Caution The pins mounted depend on the product. Refer to Caution 2 at the beginning of this chapter.
DC Characteristics (4/5)
(T
A
=
−
40 to +85
°
C, 1.8 V
≤
V
DD
≤
5.5 V, AV
DD
≤
V
DD
, V
SS
= AV
SS
= 0 V)
Parameter Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Square wave input
3.2
5.5
mA
f
XH
= 20 MHz,
V
DD
= 5.0 V
Note 2
Resonator connection
4.5
6.9
mA
Square wave input
3.2
5.5
mA
f
XH
= 20 MHz,
V
DD
= 3.0 V
Note 2
Resonator connection
4.2
6.6
mA
Square wave input
1.6
2.8
mA
f
XH
= 10 MHz,
V
DD
= 5.0 V
Notes 2, 3
Resonator connection
2.3
3.9
mA
Square wave input
1.5
2.7
mA
f
XH
= 10 MHz,
V
DD
= 3.0 V
Notes 2, 3
Resonator connection
2.2
3.2
mA
Square wave input
0.9
1.6
mA
f
XH
= 5 MHz,
V
DD
= 3.0 V
Notes 2, 3
Resonator connection
1.3
2.0
mA
Square wave input
0.7
1.4
mA
f
XH
= 5 MHz,
V
DD
= 2.0 V
Notes 2, 3
Resonator connection
1.0
1.6
mA
f
RH
= 8 MHz, V
DD
= 5.0 V
Note 4
1.4
2.5
mA
f
SUB
= 32.768 kHz,
V
DD
= 5.0 V
Note 5
Resonator connection
11
30
μ
A
I
DD1
Operating
mode
f
SUB
= 32.768 kHz,
V
DD
= 3.0 V
Note 5
Resonator connection
6
28
μ
A
Square wave input
0.8
2.6
mA
f
XH
= 20 MHz,
V
DD
= 5.0 V
Note 2
Resonator connection
2.0
4.4
mA
Square wave input
0.8
2.6
mA
f
XH
= 20 MHz,
V
DD
= 3.0 V
Note 2
Resonator connection
1.7
4.1
mA
Square wave input
0.4
1.3
mA
f
XH
= 10 MHz,
V
DD
= 5.0 V
Notes 2, 3
Resonator connection
1.0
2.4
mA
Square wave input
0.4
1.3
mA
f
XH
= 10 MHz,
V
DD
= 3.0 V
Notes 2, 3
Resonator connection
0.7
2.1
mA
Square wave input
0.2
0.65
mA
f
XH
= 5 MHz,
V
DD
= 3.0 V
Notes 2, 3
Resonator connection
0.5
1.1
mA
f
RH
= 8 MHz, V
DD
= 5.0 V
Note 4
0.4
1.2
mA
f
SUB
= 32.768 kHz,
V
DD
= 5.0 V
Note 5
Resonator connection
9
25
μ
A
I
DD2
HALT
mode
f
SUB
= 32.768 kHz,
V
DD
= 3.0 V
Note 5
Resonator connection
4
24
μ
A
STOP mode
1 20
μ
A
Supply current
Note 1
I
DD3
Note 6
T
A
=
−
40 to +70
°
C
1 10
μ
A
Remarks 1.
f
XH
: High-speed system clock frequency (X1 clock oscillation frequency or external main system clock
frequency)
2.
f
RH
: Internal high-speed oscillation clock frequency
3.
f
SUB
: Subsystem clock frequency (XT1 clock oscillation frequency)
(Notes on next page)