CHAPTER 16 SERIAL INTERFACE IICA
User’s Manual U19780EJ2V0UD
485
(4) Operation without communication
(a) Start ~ Code ~ Data ~ Data ~ Stop
ST
AD6 to AD0
R/W ACK
D7 to D0
D7 to D0
ACK
ACK
SP
1
1: IICAS0 = 00000001B
Remark
: Generated only when SPIE0 = 1
(5) Arbitration loss operation (operation as slave after arbitration loss)
When the device is used as a master in a multi-master system, read the MSTS0 bit each time interrupt request
signal INTIICA0 has occurred to check the arbitration result.
(a) When arbitration loss occurs during transmission of slave address data
(i) When WTIM0 = 0
ST
AD6 to AD0
R/W ACK
D7 to D0
D7 to D0
ACK
ACK
SP
3
4
2
1
1: IICAS0 = 0101×110B
2: IICAS0 = 0001×000B
3: IICAS0 = 0001×000B
4: IICAS0 = 00000001B
Remark
: Always
generated
: Generated only when SPIE0 = 1
×:
Don’t