CHAPTER 20 STANDBY FUNCTION
User’s Manual U19780EJ2V0UD
549
Figure 20-6. STOP Mode Release by Interrupt Request Generation (1/2)
(1) When high-speed system clock (X1 oscillation) is used as CPU clock
Normal operation
(high-speed
system clock)
Normal operation
(high-speed
system clock)
Oscillates
Oscillates
STOP
instruction
STOP mode
Wait
(set by OSTS)
Standby release signal
Oscillation stabilization wait
(HALT mode status)
Oscillation stopped
High-speed
system clock
(X1 oscillation)
Status of CPU
Oscillation stabilization time (set by OSTS)
Interrupt
request
(2) When high-speed system clock (external clock input) is used as CPU clock
• When AMPH = 1
Interrupt
request
STOP
instruction
Standby release signal
Status of CPU
High-speed
system clock
(external clock input)
Oscillates
Normal operation
(high-speed
system clock)
STOP mode
Oscillation stopped
Oscillates
Normal operation
(high-speed
system clock)
Wait
Note
Supply of the CPU
clock is stopped
(160 external
clocks)
• When AMPH = 0
Interrupt
request
STOP
instruction
Standby release signal
Status of CPU
High-speed
system clock
(external clock input)
Normal operation
(high-speed
system clock)
Oscillates
STOP mode
Oscillation stopped
Wait
Note
Normal operation
(high-speed
system clock)
Oscillates
Note
The wait time is as follows:
• When vectored interrupt servicing is carried out:
17 or 18 clocks
• When vectored interrupt servicing is not carried out:
11 or 12 clocks
Remark
The broken lines indicate the case when the interrupt request that has released the standby mode
is acknowledged.