CHAPTER 16 SERIAL INTERFACE IICA
User’s Manual U19780EJ2V0UD
494
16.6 Timing Charts
When using the I
2
C bus mode, the master device outputs an address via the serial bus to select one of several
slave devices as its communication partner.
After outputting the slave address, the master device transmits the TRC0 bit (bit 3 of the IICA status register 0
(IICAS0)), which specifies the data transfer direction, and then starts serial communication with the slave device.
Figures 16-32 and 16-33 show timing charts of the data communication.
The IICA shift register (IICA)’s shift operation is synchronized with the falling edge of the serial clock (SCLA0). The
transmit data is transferred to the SO latch and is output (MSB first) via the SDAA0 pin.
Data input via the SDAA0 pin is captured into IICA at the rising edge of SCLA0.