CHAPTER 14 SERIAL INTERFACE UART6
User’s Manual U19780EJ2V0UD
364
Figures 14-1 and 14-2 outline the transmission and reception operations of LIN.
Figure 14-1. LIN Transmission Operation
LIN Bus
Wakeup
signal frame
8 bits
Note 1
55H
transmission
Data
transmission
Data
transmission
Data
transmission
Data
transmission
13-bit
Note 2
SBF
transmission
Sync
break field
Sync field
Identifier
field
Data field
Data field
Checksum
field
TX6
(output)
INTST6
Note 3
Notes 1.
The wakeup signal frame is substituted by 80H transmission in the 8-bit mode.
2.
The sync break field is output by hardware. The output width is the bit length set by bits 4 to 2 (SBL62
to SBL60) of asynchronous serial interface control register 6 (ASICL6) (see
14.4.2 (2) (h) SBF
transmission
).
3.
INTST6 is output on completion of each transmission. It is also output when SBF is transmitted.
Remark