CHAPTER 9 REAL-TIME COUNTER
User’s Manual U19780EJ2V0UD
305
9.4.4 1 Hz output of real-time counter
Set output of 1 Hz after setting 0 to RTCE first.
Figure 9-22. 1 Hz Output Setting Procedure
RTCE = 0
RTCE = 1
Start
Stops counter operation.
RCLOE1 = 1
Enables output of RTC1HZ pin (1 Hz).
Starts counter operation.
Output start from RTC1HZ pin
9.4.5 32.768 kHz output of real-time counter
Set output of 32.768 kHz after setting 0 to RTCE first.
Figure 9-23. 32.768 kHz Output Setting Procedure
RTCE = 0
RTCE = 1
Start
Stops counter operation.
RCLOE0 = 1
Enables output of RTCCL pin (32.768 kHz).
Starts counter operation.
32.768 kHz output
start from RTCCL pin
9.4.6 512 Hz, 16.384 kHz output of real-time counter
Set outputs of 512 Hz and 16.768 kHz after setting 0 to RTCE first.
Figure 9-24. 512 Hz, 16.384 kHz output Setting Procedure
RTCE = 0
RTCE = 1
Start
Stops counter operation.
RCLOE2 = 1
Output of RTCDIV pin is enabled.
512 Hz Output: RCKDIV
= 0
16.384 kHz Output: RCKDIV
= 1
Selects output frequency of
RTCDIV pin.
Starts counter operation.
512 Hz or 16.384 kHz
output start from RTCDIV pin