CHAPTER 23 LOW-VOLTAGE DETECTOR
User’s Manual U19780EJ2V0UD
574
Figure 23-5. Timing of Low-Voltage Detector Internal Reset Signal Generation
(Detects Level of Supply Voltage (V
DD
)) (1/2)
(1) In 1.59 V POC mode (option byte: POCMODE = 0)
Supply voltage (V
DD
)
<3>
<1>
Time
LVIMK flag
(set by software)
LVIF flag
LVIRF flag
Note 3
Note 2
LVI reset signal
POC reset signal
Internal reset signal
Cleared by
software
Not cleared
Not cleared
Not cleared
Not cleared
Cleared by
software
<4>
<7>
Clear
Clear
Clear
<5> Wait time
LVION flag
(set by software)
LVIMD flag
(set by software)
H
Note 1
L
LVISEL flag
(set by software)
<6>
<2>
V
LVI
V
POC
= 1.59 V (TYP.)
Notes 1.
The LVIMK flag is set to “1” by reset signal generation.
2.
The LVIF flag may be set (1).
3.
LVIRF is bit 0 of the reset control flag register (RESF). For details of RESF, see
CHAPTER 21
RESET FUNCTION
.
Remark
<1> to <7> in Figure 23-5 above correspond to <1> to <7> in the description of “When starting
operation”
in
23.4.1 (1) When detecting level of supply voltage (V
DD
)
.