Vertical Inline Power Vent Terminations - Flex Pipe
Roof Pitch Minimum Vent Height
Feet Meters
flat to 7/12
2
0.6
over 7/12 to 8/12
2
0.6
over 8/12 to 9/12
2
0.6
over 9/12 to 10/12
2-1/2
0.76
over 10/12 to 11/12
3-1/4
1
over 11/12 to 12/12
4
1.2
over 12/12 to 14/12
5
1.5
over 14/12 to 16/12
6
1.8
over 16/12 to 18/12
7
2.1
over 18/12 to 20/12
7-1/2
2.3
over 20/12 to 21/12
8
2.4
Diagram 4
20. Put a bead of caulking on the exterior between the outer pipe and flashing
to prevent water from penetrating the chimney system.
21. Slide storm collar over pipe length until it reaches the flashing.
22. Install termination cap by twist locking it.
23. Secure the flashing to the roof using screws.
Diagram 3
Diagram 3a
Diagram 3b
19. Slide the finished length up towards the flashing. Ensure the length
of pipe is a minimum of 2 feet (610 mm) measured from the top of
the roof. Level the chimney and secure it to the bottom side of the
roof using the roof support provided with the kit and a minimum of 2
screws per side (see Diagram 3b). See Diagram 4 for roof pitch and
height requirements. See Diagram 3a for securing method. If 2 ft. (610
mm) is insufficient and additional lengths are required, these may be
purchased separately. See the Simpson Duravent components list in
the instruction manual for part numbers.
Flex Pipe
Ceiling Firestop
Roof Support / Brace
Flashing
Storm Collar
Termination Cap
Ceiling Firestop
Inline Power Vent Terminal
Inner Pipe Adaptor (shown inside flex pipe)
Enclosure
Flex Pipe
Ceiling Firestop
Roof Support
Flashing
Elbow Support
Termination Cap
Storm Collar
Ceiling Firestop
Support to prevent sagging
Inline Power Vent Terminal
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
NO
TE
• Any closets or storage spaces that the vent passes through must
be enclosed.
Summary of Contents for City CST60E-LP
Page 125: ...City Series CST60E 125 notes ...
Page 130: ...130 City Series CST60E warranty ...
Page 131: ......