City Series CST60E
|
27
installation - general
Option 3 - Both Sides
A
2" (0 - 51 mm) max.
B
120 sq. in. min.
C 4" (102 mm) min.
D 10" (254 mm) min.
Shown with ventilation openings on both sides (60 sq. in.) to meet the minimum
requirement of 120 sq. in.
When ventilation openings are on both sides with the second open-
ing in another room (two different pressure zones), ventilation openings must be the same size to
balance air flow.
A
B
C
D
Option 4 - One Side
A
2" (51 mm) max.
B
120 sq. in. min.
C 4" (102 mm) min.
D 10" (254 mm) min.
Shown with ventilation opening on one side to meet the minimum requirement of
120 sq. in.
A
B
C
D
2nd ventilation opening
in separate room