City Series CST60E
installation-power vent
Gas Power Vent Installation--Wiring the Power Vent to the Unit
920-399
06.14.21
1
CST60E -
Gas Power Vent Installation-Wiring-End of Line Power Vent
1. Remove exterior side panels and bottom panels (if installed) to gain
access to junction box (Diagram 1).
BX cable through strain relief
Remove 2 panels
(single-sided
models)
Remove 1 panel
(3-sided models)
2. Remove access panel by lifting panel up and out (Diagram 2). Unscrew
1 x Phillips head screw to gain access to junction box (Diagram 3).
5. Strip 24" of BX exposing wires, then run BX through strain relief on right
side of the unit into the junction box (Diagrams 4 & 5).
Remove 1 Screw
Strain relief
Diagram 1
Single-sided model shown
Diagram 5
Diagram 2
Diagram 3
Diagram 4
Remove Access
Panel
3. Locate the white and black power cables. Cut the connectors off
and strip the wires.
4. Locate the red and blue cables. Remove the twist-on wire connector.
6. Join Powervent and BX cable wires together by firstly splicing 1" off wires--
join black to black, white to white (Diagram 6).
Diagram 6
NO
TE
The ground wire must stay out of the junction box as this will
be attached later. Only the 4 colored wires go into the junction
box.