114
|
City Series CST60E
maintenance
NO
TE
• If you have an incorrect flame pattern, contact
your Regency
®
dealer for further instructions.
NO
TE
• Improper positioning of logs may create
carbon buildup and will alter the unit's
performance, which is not covered under
warranty.
W
ARNINGS
• Do not clean the glass when it is hot.
• The use of substitute glass will void
product warranties.
• Care must be taken to avoid glass
breakage.
• Do not strike or abuse the glass.
• Do not operate this fireplace without
the glass, or with cracked or broken
glass.
• Wear gloves and safety glasses when
removing broken glass.
• Replacement of glass panels should
be done by a licensed service person.
NO
TE
• Never operate the appliance without
the glass properly secured in place.
General Vent Maintenance
Conduct an inspection of the venting system semi-
annually. Areas to inspect are listed below.
1. Check the venting system for corrosion in areas
exposed to the elements. These will appear as
rust spots or streaks, and in extreme cases,
holes. These components should be replaced
immediately.
2. Remove the cap and shine a flashlight down
the vent. Remove any bird nests or other foreign
material.
3. Check for excessive condensation, such as
water droplets in the inner liner and dripping
out the joints. Continuous condensation can
cause corrosion of caps, pipe, and fittings.
Condensation may be caused by excessive
lateral runs, too many elbows, and exposing
exterior portions of the system to cold weather.
4. Inspect joints to verify that pipe sections or
fittings are not disturbed or loosened. Also,
check mechanical supports such as wall straps
or plumbers' tape for rigidity.
Log Replacement
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening the door and carefully removing
the logs. If a log needs replacing, you must use
the proper replacement log. The position of these
logs must be as shown in the diagrams in the "
Optional Driftwood Log Set Installation" section
of this manual.
Glass Gasket
If the glass seal requires replacement, a graphite
seal specifically designed for this appliance is
required (part # 726-556/P for the complete set).
These are applied with self adhesive tape.
Gasket is also installed on the sides of the inner
glass to protect against breakage during installation.
The gasket part number is 936-222, sold by the
foot. Three feet are required to complete both sides.
Glass
Your Regency
®
fireplace is supplied with high
temperature 5mm-tempered outer glass & 5mm-
ceramic inner glass. If your glass needs cleaning,
use an approved glass cleaner available at any
authorized dealer. Do not use abrasive materials.
Glass Replacement
Maintenance Instructions
1. Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a soft clean paint
brush as the logs are fragile.
2. Clean appliance and door with a damp cloth
and a gas fireplace glass cleaner (never when
unit is hot). Never use an abrasive cleaner. The
glass should be cleaned when it starts looking
cloudy.
3. The fireplace is finished with heat resistant
paint and should be refinished with the same.
Regency
®
uses StoveBright Paint - Metallic
Black #6309.
4. Periodically check the burner for position and
condition. Visually check the flame of the burner,
making sure it is steady, not lifting or floating.
If there is a problem, call a qualified service
person.
5. The appliance and venting system must be
inspected before use and at least annually by
a qualified field service person to ensure that
the flow of combustion and ventilation air is not
obstructed.
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact with
the rear burner or flame sensor.
Flame Pattern
Periodically check the pilot and main burner flames.
Correct pilot flame pattern has two strong blue
flames: 1 flowing around the flame sensor and 1
flowing across the burner (it does not have to be
touching the burner).
Correct main burner flame pattern
If your glass breaks, purchase a replacement from
an authorized Regency dealer. Replacement glass
is shipped already installed into the door frame.
Reinstall per the instructions in the "Inner Glass
Panel (Firebox Glass) Installation / Removal" section
of this manual.
CST60E REPLACEMENT GLASS:
Outer safety glass front - tempered
(Part# 940-519/P)
Inner glass front - ceramic (part# 940-518/P)
6. Do not use this appliance if any part was under
water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control submerged.
7. When this appliance is serviced, check that
the vent-air system was properly resealed &
reinstalled in accordance with the manufacturer's
instructions.
8. Verify operation after servicing.
Summary of Contents for City CST60E-LP