City Series CST60E
|
43
installation - general
LP Conversion Instructions
920-406
07.14.21
1
CITY SERIES 60
CONVERSION FROM NG TO LP
CST60E using SIT 885 NOVA Gas Valve
Always let the appliance cool to room temperature before servicing.
1 Remove the outer panels and safety glass — see manual.
2. Remove inner firebox glass — see manual.
3. Remove inner panels — see manual.
4. Remove all media installed on burner (glass, logs or stones, etc).
5. Lift off the far right base panel and loosen 2 screws on IFC cover--re-
moved cover to access IFC.
6. Disconnect the cable coming from the pressure regulator motor.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
Cable from motor
Conversion Kit 686-969 includes:
1
911-191
Stepper Motor LP for 885 SIT
1
905-046
Orifice #50
1
910-037
Pilot Orifice #30
1
918-590
Decal - Conversion to LP
1
908-528
Label Propane
1
904-529
5/32" long Allen Key
1
920-406
Instruction Sheet
7. Remove and discard 2 pressure regulator screws (A) using a (T20 or slot
screwdriver), the pressure regulator (B), and the spring and diaphragm
(C - see below).
8. Ensure that the rubber gasket, prefitted as part of the assembly, is
properly positioned. Install the new pressure regulator using the 2x M4
x .7 screws supplied. Tighten the screws to 25lb-in. In the event that
the screw threads are cross-threaded or stripped, replace the valve as-
sembly.
Install the enclosed propane identification label to the valve body where it is
easily seen.
Pressure
regulator
screws
9. Re-attach the pressure regulator wire (disconnected in step 6), re-situate
the IFC, and secure the screws that fasten the IFC mounting brackets.
10. Remove the pilot hood by lifting it up and off.
tooltip
11. Lift off the trim cover on the right side of the burner. Also, remove the burner
surround by sliding it to the left and lifting it off.
Trim cover
Burner Surround
Pilot hood
W
ARNING
• This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements
of the authority having jurisdiction. If these instructions
are not followed exactly, a fire, an explosion, or produc-
tion of carbon monoxide may result causing property
damage, personal injury, or loss of life. The qualified
service agency is responsible for the proper installa-
tion of this kit. The installation is not complete until the
operation of the converted appliance is checked, as
specified in the manufacturer’s instructions supplied
with the kit.
CA
UTION
• The gas supply shall be shut off prior to disconnecting
the electrical power, before proceeding with the conver-
sion.