36
|
City Series CST60E
installation - general
40
|
City Series CV60E
Chase Vent Installation (White Front)
Framed Opening must be between 3” and 3.5” tall, and at least 60.25” wide to accomodate the Chase vent.
The top of the chase vent opening must be 2” or less from the top of the chase enclosure.
Max 2” (51 mm)
Ceiling
Ceiling
Top of chase enclosure
Max 2” (51 mm)
Stud
Stud
Stud
Stud
60” (1524 mm) Chase Vent
Finishing material
Finishing material
Opening for vent
3”-3.5”
Min 60.25”
60” (1524 mm) Chase Vent
Chase Vent Installation (White Front) (Part # 686-991)
A
60-1/2" (1537 mm)
B
Opening for vent: 3-1/4" (83 mm) - 3-1/2" (89 mm)
B
A
NO
TE
• This chase vent is only used when accommodating a 180 sq. in. ventilation opening.
Summary of Contents for City CST60E-LP
Page 125: ...City Series CST60E 125 notes ...
Page 130: ...130 City Series CST60E warranty ...
Page 131: ......