90
|
City Series CST60E
installation-power vent
Gas Power Vent Installation - Wiring - End of Line Power Vent
13-1/2"
13-1/2"
Determine
the correct
height
1. Frame an opening to the outside of the building at 13-1/2" W x
13-1/2" H (343 mm x 343 mm) to accommodate the power vent.
6. Determine the building finishing material thickness.
7. Depending on the building material thickness, install the frame onto the
power vent mount using four screws. Mounting holes start at 2" (51 mm)
from the front of the power vent unit cover and can be adjusted back in
3/4" (19 mm) increments.
NOTE: Exterior finishes such as thin vinyl siding may warp if closer than
2” (51 mm) to the vent. For interior installations on vinyl siding, a 2” (51
mm) frame/buffer zone must be created between the finishing and the vent.
Determine protrusion
Determine finishing
Set frame depth
(starting @ 2" of
faceplate protrusion)
material thickness
of faceplate
2. Run the venting and BX cable from the unit to the framed opening.
3. Install the strain relief (supplied) to the back of the power vent mount box.
4. Strip the sheath from the BX cable to expose approximately 8" (203
mm) of exposed wires.
5. Feed the BX cable through the strain relief installed in step 3.
Strain Relief
Adjustable Power Vent Frame
8. Install power vent unit into framed opening using four screws as
shown below.
9. Seal the edges of the power vent unit to the framing (there are two
seams).
Seal behind flange with silicone--
screw against
Plywood siding.
Wipe
any excess silicone off outer flange
after flange is screwed down.
Silicone edge of inner trim
against siding of structure,
wipe any excess silicone off
trim.
Fan discharge
opening
W
ARNING
• Electrical connections should only be carried out by a
licensed electrician.