50
|
City Series CST60E
installation-non power vent
Venting Introduction
The CST60E uses the "balanced flue" technology co-axial system. The inner liner vents products of combustion to the outside while the outer liner draws
outside combustion air into the combustion chamber, thereby eliminating the need to use heated room air for combustion and losing warm room air up the
chimney.
Venting Arrangement for Horizontal Terminations (Rigid and Flex)
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
o
elbow (two 45
o
elbows equal one 90
o
elbow).
• Maintain clearances to combustibles as listed in "Clearances" section
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
• A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 0.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required.
46-1/4" (1175 mm)
Minimum Height
Requirement
Vent Restrictor
Set 3: 2-3/8" Open
Vent Restrictor
Set 2: 3-1/8" Open
Set 0
Fully Open
Factory Set
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or
gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
NO
TE
• These flue pipes must not be connected to any other appliance.
NO
TES
• Must use optional rigid pipe adapter (part# 770-994) when using rigid pipe venting systems.
• For horizontal terminations, the Regency direct vent flex system may be used for installations with a maximum continuous vent length of up to 10 feet.
If longer runs are required, rigid pipe must be used.