City Series CST60E
|
75
installation-power vent
Vertical Inline Power Vent Terminations - Rigid Pipe
920-210b
09.22.20
3
CV72EPV/CB72EPVCB40EPV/CC40EPV/CV40EPV/CV60EPV
Inline Power Vent Vertical or Hortizontal Installation Instructions
Vertical Inline Power Vent Terminations
Rigid Pipe
The minimum components required when using inline power
vent are:
1 High Wind Cap
1 Rigid Pipe Adaptor (770-994)
1 Ceiling Firestop
1 Flashing
1 Storm Collar
1 Lengths of pipe to suit wall thickness & vent run
(see chart)
1 Vent Reducer
1 Inline Power Vent Kit
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be used to secure rigid
pipe to adaptor.
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the vent cap meets the minimum height
requirements specified in table below or local codes. Note that for
steep roof pitches, the vertical height must be increased. A poor
draft, or down drafting can result from high wind conditions near
big trees or adjoining roof lines, in these cases, increasing the
vent height may solve the problem.
Roof Pitch
Minimum Vent Height
Feet
Meters
flat to 7/12
2
0.6
over 7/12 to 8/12
2
0.6
over 8/12 to 9/12
2
0.6
over 9/12 to 10/12
2-1/2
0.8
over 10/12 to 11/12
3-1/4
1
over 11/12 to 12/12
4
1.2
over 12/12 to 14/12
5
1.5
over 14/12 to 16/12
6
1.8
over 16/12 to 18/12
7
2.1
over 18/12 to 20/12
7-1/2
2.3
over 20/12 to 21/12
8
2.4
This product was evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct
Venting, ICC Excel Direct, Olympia Ventis DV, and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of components.
Rigid Pipe Adaptor
High Wind Cap
Storm Collar
Ceiling Firestop
Flashing
Inline Power Vent Kit
Vent Reducer
Lengths of Pipe
Lengths of Pipe
Slip Section
W
ARNING
•
• Do not combine venting components from different venting
Do not combine venting components from different venting
systems.
systems.