background image

INSTALLATION AND OWNERS MANUAL

DOUBLE SIDED UNITS

OPEN FIREPLACES

INSTALLATIONS TO COMPLY WITH

AS/NZS2918:2018 AND WILL REQUIRE A

BUILDING CONSENT

IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these

instructions may result in a fire hazard and will void the warranty.

WARNING

Fire Risk.

For use with solid wood fuel only.
Other fuels may over fire and generate poisonous
gases (i.e. carbon monoxide).

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or

any other appliance.

• Do not over fire - If appliance or chimney connector glows, you are over firing. Over firing will

void your warranty.

• Comply with all minimum clearances to combustibles as specified. Failure to comply may

cause a house fire.

If the information in these instructions is not followed exactly, a fire could result causing
property damage, personal injury, or death.

!

WARNING

Summary of Contents for UNIVERSAL 1050

Page 1: ...l only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do n...

Page 2: ...1 6 General use Attaching firescreen lighting a fire 12 6 General use Fuels Cleaning Maintenance Safety 12 AS NZS 2918 2018 General notes Thank you for purchasing a Jetmaster fireplace Please read thi...

Page 3: ...is with height of chimney minimum 4 6 metres as per AS NZS 2918 2018 C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly It can be...

Page 4: ...flow of outdoor air for all combustion appliances and exhaust equipment Ensure cental heating and air conditioning return vents are not located in the vicinity of the appliance Avoid installing the a...

Page 5: ...ick welded steel it is normal and expected for some imperfections and slightly out of square components It is recommended to not begin construction of cavity or flue penetration points until after the...

Page 6: ...s For gas applications an AGA approved cowl must be used C D Measurements are in mm and provided as a reference only Due to the nature of thick welded steel it is normal and expected for some imperfec...

Page 7: ...ation Note Timber framing should be constructed using normal framing methods Image above is an example only Do not install finishing materials around the cavity until after the fireplace has been inst...

Page 8: ...ector Hebel blocks must be used in front of the appliance base on both sides when installing the appliance see joint AS NZS 2918 2018 3 3 2 The floor protector should extend 500mm in front of each of...

Page 9: ...wrapped in 100mm R3 5 insulation between the PowerPanel enclosure up to the height of 200mm above the top of the gather The Flue penetration through the ceiling must have a 50mm gap in all directions...

Page 10: ...ation cap away from trees adjacent structures uneven roof lines and other obstructions Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions th...

Page 11: ...cing down Fig 5 2 Glass tape may be required to ensure a snug fit The outer flue is then installed outside active flue with crimp facing up to ensure water penetration on flue above roof runs out Rive...

Page 12: ...side towards you with the steel handle provided 2 In firebox lay your fire lighters 10 to 15 centimetres apart depending on the size of your firebox Do not use newspaper as a fire lighter On units th...

Page 13: ...S NZS 2918 General notes Fuels The quality of firewood is extremely important How long a tree has been felled or dead for does not indicate how dry the wood is The best way to dry wood is to split it...