12 - TROUBLESHOOTING
ANOMALIES RELATED TO THE PLUMBING CIRCUIT
No increase in temperature with
boiler in operation
Incorrect combustion adjustment.
Check recipe and parameters.
Boiler / system dirty.
Check and clean the boiler.
Insufficient stove power.
Check that the boiler is properly sized for
the requirements of the system.
Poor pellet quality
Use quality pellets.
Condensation in boiler
Incorrect temperature setting.
Set the boiler to a higher temperature.
Insufficient fuel consumption.
Check the recipe and/or technical
parameters.
Radiators cold in winter
Room thermostat (local or remote) set
too low. If remote thermostat, check if it
is defective.
Set to higher temperature or replace. (if
remote)
Circulator does not run because blocked.
Free up the circulator by removing
the plug and turning the shaft with a
screwdriver.
Circulator does not run.
Check the electrical connections of the
circulator; replace if necessary.
Radiators have air in them
Vent the radiators
ATTENTION!
The operations in italics must be carried out by specialised personnel.
The manufacturer will not be liable and the guarantee lapses if this condition is not respected.