16
2 - MENU OPTIONS
l - System configuration (see dedicated chapter)
Modify the system configuration (with the boiler off) as follows:
•
Press the ''menu'' key.
•
Use the arrow keys to scroll through and select "Settings"
•
Press 3 “menu” to confirm.
•
Use the arrow keys to scroll through and select ''System configuration''
•
Press 3 “menu” to confirm.
•
Use the + - keys to modify the configuration between 01 and 06.
•
Press "menu" to confirm and "esc" to exit.
m - Season
In configurations 2, 3 and 4, enabling the "summer" function disables deviation of the 3-way valve towards the heating system to prevent
the radiators from heating up, and so the flow is always towards the hot water system (ACS).
Modify the function as follows:
•
Press the ''menu'' key.
•
Use the arrow keys to scroll through and select "Settings"
•
Press 3 “menu” to confirm.
•
Use the arrow keys to scroll through and select ''Season''
•
Press 3 “menu” to confirm.
•
Use the + - keys to select "Summer" or "Winter".
•
Press "menu" to confirm and "esc" to exit.
n
- Solar
The integrated solar power system can be enabled only in system configurations 4 and 6.
The solar system must be configured by a qualified technician.
0 - Technical menu (for assistance ccentres only)
A password is required to access the
technical menu
Access the "technical menu" as follows:
•
Press the ''menu'' key.
•
Use the arrow keys to scroll through and select "Settings"
•
Press 3 “menu” to confirm.
•
Use the arrow keys to scroll through and select ''Technical menu''
•
Press 3 “menu” to confirm.
•
Enter the password
•
Use the + - keys to select "Product type", "Service", "Parameters", "Sanitary Par", "Counter memories", "Puffer data" and "Climatic
curve" and make any necessary changes.