18
1
3
2
5
4
7 - SYSTEM CONFIGURATION
SYSTEM CONFIGURATIONS
At the time of installation, the product must be configured according to the type of system by selecting the relative parameter in the
technical menu.
There are 6 possible configurations, described below:
Configuration
Description
1
Ambient temperature management with external ambient thermostat
2
Ambient temperature management with external ambient thermostat; instant production of hot sanitary water
with plate exchanger in FACTORY CONFIGURATION.
3
Ambient temperature management with external ambient thermostat; production of hot sanitary water for
boiler with thermostat and 3-way diverter valve (optional).
4
Ambient temperature management with external ambient thermostat; production of hot sanitary water with
boiler with ntc probe (10 kΩ ß3435) and 3-way diverter valve (optional).
5
External Puffer management controlled by thermostat (optional).
6
External puffer management controlled by ntc probe (10 kΩ ß3435) (optional).
CONFIGURATION 1
Summary of Contents for LOGIKA 25-35 REFILL
Page 52: ...50 y x S v 7 INSTALLATION AND ASSEMBLY OFTANK ASSEMBLYOFSIDEPANEL MANUALTANK ...
Page 121: ......
Page 122: ......
Page 123: ......