8.4
Making the cable connections
8.4.1
General information about establishing on-board wiring
Caution!
When establishing cable connections ensure that the
cables are disconnected from the power supply.
It is essential to ensure that all cables are disconnected
from the power supply, if necessary measure the voltage
beforehand and/or disconnect the relevant distributor.
In order to ensure that the compass operates correctly, it is essential that you follow the
procedures described below for establishing cable connections.
Cable type CAN bus and RS422 interface (manufacturer’s recommendation):
6x0.75mm
2
, twisted with screening.
Cable type voltage supply Raytheon cable no. WN219--401--3.0 with connected plug or
3x0.75mm
2
, twisted.
-- Strip approx. 180 mm of the cable length.
Make sure you do not damage the screening.
-- Strip off the screening leaving a remaining section measuring approximately 15mm
and strip off over the outer insulation (see Figure 76).
appr. 180 mm
appr.
15 mm
Figure 76
: How to strip the connection cable