Note: LED Fault indication
Downloading new firmware ≥2.5.x onto existing older models of VAR2-IPPOE-i6-1
and VAR2-IPPOE-i8-1 (Possible False LED Fault Indication).
If the system indicates a potential LED fault the following warning will appear:
If you are performing the above download onto an older product you may get
false LED fault indication.
Physically check the product to make sure all LEDS are working (please observe
eye safety precautions – see safety information section).
If all LEDs are illuminated follow the instructions in the above warning and tick
the box on the Advanced Settings page. Press save on this page to implement
the change.
This should remove the false fault indication.
After this process if all LEDS are illuminated and you are still getting an LED fault
indication please contact Raytec.
802.3 bt PoE Standard Compatibility
VARIO2 IPPOE 8 size (24 LED) products and VARIO2 IPPOE 16 size (48 LED)
products with a Factory Software version ≥2.5.x are compliant to the 802.3 bt
PoE standard. When using one of these products if you are using non 802.3 bt
PSE you will get a warning message on this page asking you to check you have
sufficient power.