At the bottom of the page is additional diagnostic information that is saved to the
lamp to show statistics from the lamp’s
(Total)
lifetime. (Software version 2.5.x
or above only).
The Max Volts is the max voltage that the illuminator has seen and the Duration -
Lamp On (Total) and Duration - Power Connected (Total) are similar to the fields
above but display the values over the lifetime of the illuminator (These values are
not lost when power cycling the illuminator). These diagnostics are intended to
help Raytec Technical Support but can also be useful to the user to view lifetime
information about their illuminator.
Input Voltage Status
Green LED – Input voltage correctly within
specified range
Amber LED – Potential fault
Check Adv Diagnostics for more information
LED Status
Green LED – All LED strings of illuminator
operating correctly
Amber LED – Potential fault
Grey LED – LED status is unknown e.g. LEDs not
currently on.
Check Adv Diagnostics for more information
Photocell Status
Indicates if photocell status is day or night
Ext Input Status
Indicates if external input is being received (active)
or not (inactive)
Auxiliary Output Status
Indicates if external output is active (closed) or
not (open)
Deterrent Pattern
Indicates which deterrent pattern is selected
Duration – Lamp On
Indicates the amount of time the illuminator has
been on from last power on
Duration – Power
connected
Indicates the amount of time the illuminator has been
connected to a power source from last power on.