External Output
(Fault option only available with Software version 2.5.x or above)
The External Output is a volt free short/ open output.
External Output Trigger State: The drop down box gives you the option to disable
the external output signal or make the signal dependent on active states of either
the photocell, External Input, a combination of the two or respond to a fault.
(Photocell Active State = Darkness. External Input Active State = Valid Trigger
received.)
Fault relates to input voltage or LED fault. If you set the Active State to Open Circuit/
High, the fault option also provides a means of informing you when the lamp has
lost power.(With active state set to Open Circuit/High in a no fault condition you will
get a constant signal which will stop if you lose power to the lamp).
Note: LED fault indication is suppressed if the illuminator is set to
deterrent pattern output
The External Output active state, provided above conditions are met, can be
selected to be open / high or closed / low.
Note: External Output is triggered by the local illuminator Photocell and
the local illuminator External Input or Fault condition.
Factory Default:
Photocell Only
Factory Default:
Short Circuit / Low