56
raytecled.com
Raytec Global Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Hard Reset Button - Located on illuminator
A hardware reset button feature has been provided that will restore ALL factory
default settings including
IP address, user names and passwords
etc. and can
be used in cases where communication is lost and the illuminator does not respond.
WARNING: We recommend attempting to reconnect with the illuminator
by firstly restarting the illuminator or restoring factory settings via the
integrated web interface. The hard reset button on the illuminator should
be used only as a last resort.
To reset all parameters and the IP address to Factory Default settings:
1. Disconnect power from the illuminator.
2. Remove the baseplate on the illuminator to access the reset button.
3. Press and hold the Reset button and reconnect power.
4. Keep the Reset button pressed for approximately 5 seconds until the
illuminator flashes. Release the Reset button.
5. Replace the baseplate securely to ensure unit remains waterproof. (Baseplate
fixing screws: Torque 0.6Nm)
The illuminator can now be discovered using the Raytec DiscoMan Tool and can
be configured as normal following the instructions in this manual. Be aware that
the network settings will have been reset to the factory default:
Vario2 IPPOE with software 2.5.x or above: IP address obtained automatically
via DHCP.
Vario2 IPPOE with software < 2.5.0: Static IP address 192.168.2.80.
Hard Reset Button
Baseplate fixing screws: Torque 0.6Nm