Trigger Control
For both Photocell and External Input, the user can select 3 action states:
1. Inactive
The illuminator ignores the input
2. Lamp Control
The illuminator will respond to its own input
3. Group Control The illuminator will respond to an input from illuminators
within its group – based on selection from Respond to
Group Commands below
Factory Defaults: Photocell
Lamp Control
External Input
Lamp Control
Respond to Group Commands
If Group control is NOT selected from Trigger Control options, then the illuminator
will not respond to any Group commands.
If Group Control is selected from Trigger Control options, then the user can select
two modes of operation in response to Group Commands:
1. Yes, Send & Receive The illuminator will both originate group commands
based on the trigger AND respond to group
commands from other illuminators in its group.
2. Yes, Receive only
The illuminator will only respond to group
commands from other illuminators in its group but it
will NOT originate any group commands.
Factory Defaults: Photocell
No, ignore group commands
External
Input No, ignore group commands