Remote Control - SCPI
R&S
®
QAR
75
User Manual 1178.7200.02 ─ 04
MEASurement:TRANsmission:BAND<n>:STATistics<m>:MEAN?
This command queries the one-way mean attenuation of the transmission measure-
ment.
Suffix:
<n>
.
1: First evaluated frequency band.
2: Second evaluated frequency band.
<m>
1: Logarithmic result.
2: Linear result.
You can query the unit of a result with
TRANsmission:BAND<n>:STATistics<m>:UNIT?
Return values:
<Tranmission>
Default unit: dB
Example:
//Query logarithmic result of second frequency band
MEAS:TRAN:BAND2:STAT1:MEAN?
Usage:
Query only
MEASurement:TRANsmission:BAND<n>:STATistics<m>:UNIT?
This command queries the unit of a result.
Suffix:
<n>
.
1: First evaluated frequency band.
2: Second evaluated frequency band.
<m>
1: Logarithmic result.
2: Linear result.
Return values:
<Unit>
String that contains the unit of a result.
Example:
//Query unit of the first result in the second frequency band.
MEAS:TRAN:BAND2:STAT1:UNIT?
Usage:
Query only
MEASurement:TRANsmission:BAND<n>:STOP:FREQuency?
This command queries the stop frequency of the transmission measurement.
Suffix:
<n>
.
1: First evaluated frequency band.
2: Second evaluated frequency band.
Return values:
<StopFrequency>
Default unit: GHz
Example:
//Query stop frequency of second frequency band
MEAS:TRAN:BAND2:STOP:FREQ?
Usage:
Query only
Remote Commands