Turns OFF phone fault detect, turns ON Auto. Tone/Pulse Select
9 1 7 2
u
Turns ON BOTH Phone Fault Detect and Auto. Tone/Pulse Select
(default)
9 1 7 3
Note:
The factory default setting for code 917 is parameter 3, BOTH Phone Fault
Detect and Auto. Tone/Pulse Select ON.
Setting Automatic Tone/Pulse Selection ON when it was previously OFF will
cause the Verbatim autodialer to perform the test for Tone/Pulse Selection even
though it has been longer than one minute since the unit was last powered on or
reset.
After powering the unit on, Automatic Tone/Pulse Selection may be temporarily
suspended by any front panel activity. Automatic Tone/Pulse Selection will
then be resumed one minute after the front panel activity has ceased.
No Tone/Pulse Selection will be done while the unit is being programmed over
the phone or if there are not phone numbers programmed.
6.2.12
Call Progress Monitoring (CPM)
Call Progress Monitoring (CPM) operates by listening for the presence or
absence of busy and ringing signals. These are the same signals you hear after
you dial a phone number. Proper operation of CPM requires that the busy and
ringing signals are composed of standard Call Progress frequencies.
The possibility exists that CPM may not function properly because the CPM
tones on a particular phone system are not standard.
Unlike other equipment with Call Progress Monitoring, CPM on the Verbatim
autodialer does not include detection for the dial tone at the beginning of the
dialout session. However, dialtone detection is an integral part of Phone Fault
Detection. This allows CPM to be operational even when the Verbatim
autodialer is installed inside of a PBX phone system which has a non-standard
dialtone.
CPM is intended to detect the following phone line states:
l
phone line is busy - both subscriber and trunk busy signals are detected
l
non-existent phone number
l
phone unanswered - still ringing
l
phone answered - ringing stopped
Summary of Contents for Verbatim
Page 1: ...Verbatim Owner s Manual Owner s Manual...
Page 14: ...Overview 1 4 Verbatim Owner s Manual...
Page 22: ...Installation 2 8 Verbatim Owner s Manual...
Page 24: ...Programming and Testing 3 2 Verbatim Owner s Manual Front Panel Keys and Indicators Diagram...
Page 34: ...Recording Voice Messages 4 6 Verbatim Owner s Manual...
Page 80: ...Using the Alarm Ready Schedule Feature 7 12 Verbatim Owner s Manual...
Page 82: ...Maintenance Testing and Battery Replacement 8 2 Verbatim Owner s Manual...
Page 94: ...Verbatim Series SFP Autodialer A 8 Verbatim Owner s Manual...
Page 104: ...Analog Signal Input B 10 Verbatim Owner s Manual...
Page 108: ...Analog Signal Input B 14 Verbatim Owner s Manual...
Page 114: ...Remote Supervisory Control Output C 6 Verbatim Owner s Manual...
Page 118: ...Printer Options D 4 Verbatim Owner s Manual...
Page 126: ...Data Acquisition Central Data Logging E 8 Verbatim Owner s Manual...
Page 155: ...Cabling Diagrams Verbatim Owner s Manual G 1 G Cabling Diagrams...
Page 156: ...Cabling Diagrams G 2 Verbatim Owner s Manual G 1 RACO VSER 01 Serial Cable Connection Diagram...
Page 166: ...Verbatim Floobydust H 4 Verbatim Owner s Manual DC Power Connection Diagram AJ1 JB8 MINI PLUG...
Page 174: ...Verbatim Floobydust H 12 Verbatim Owner s Manual Heater Thermostat Mounting and Wiring Diagram...
Page 188: ...Verbatim Floobydust H 26 Verbatim Owner s Manual Motherboard Component Diagram...
Page 189: ...Verbatim Floobydust Verbatim Owner s Manual H 27 Jumper Block Diagram...
Page 192: ...Verbatim Floobydust H 30 Verbatim Owner s Manual...
Page 200: ...Verbatim Autodialer Specifications I 8 Verbatim Owner s Manual...
Page 201: ...Worksheets Verbatim Owner s Manual J 1 J Worksheets...
Page 236: ...Glossary Glossary 8 Verbatim Owner s Manual...
Page 244: ...Verbatim Owner s Manual...