21
may (however unlikely) result in a loss of the inter-
nal calibration table as the display always needs a
minimal voltage to keep the internal flash alive. The
internal capacitors will normally bridge at least 24
hours.
User controls
Some units (22“-26“) have a power switch on the
back. This needs to be switched on at first.
On the right side of the display, you will find the only
user control.
- a short click on this button opens the OSD
- a long click on the button switches the unit on/off
- turning the button up/down lets you move through
the OSD. Clicking the button lets you select a
function and again, turning will change values
Notice:
The OSD is not often used as control and
setup is performed by the iColor Display software
Notice:
When adjusting color values for a manual ca-
libration, do not increase the values above the level
of 70. Higher values would create channel clipping
and the calibration would be very unprecise.