Initializing the Storage Arrays and Software
41
DXi6902
Figure 36 PTO: Hardware
Check Menu
3
On the
Hardware Check Menu
, type the option for
Check Memory
and press
<Enter>
.
The system displays information about the installed memory (see
Make sure the memory configuration is valid before continuing (see
). If the
memory configuration is not correct, resolve the issue before continuing (see
Figure 37 PTO: Check Memory
4
On the
Hardware Check Menu
, type the option for
Check NetApp Trays
and press
<Enter>
.
The system displays information about attached Array Modules (RBODs) and
Expansion Modules (EBODS) (see
Make sure all of the installed RBODs and EBODs are detected. If one or more storage
arrays are not detected, resolve the issue before continuing (see
Figure 38 PTO: Check NetApp
Trays
*** Pick to Order Hardware Check Menu ***
0) Check Memory - check memory size to number of trays.
1) Check NetApp Trays - check for valid tray combinations.
2) Check HBAs - check for valid PCI slots and cards.
Detected Memory size: 129024 MB, (128 GB)
Memory size OK for the attached 2 tray(s) of external storage.
Array: 1
Number Of Disk Drives: 24
Controller: A
Controller: B
EBOD: 0
ESM Canister: A (Left)
ESM Canister: B (Right)
External Storage is OK.