Performing Initial Configuration
55
DXi6902
3
If the DXi6902 is configured with an optional additional Ethernet adapter (1 GbE or
10 GbE), connect the appropriate cable type:
•
Quad 1 GbE Option
- Connect up to four CAT6 Ethernet cables to the optional
1 GbE ports (6, 7, 8, and 9) (see
).
•
Dual 10 GbE (SFP+) Option
- Connect up to two 10 GbE cables (optical or
Twinax) to the optional 10 GbE ports (6 and 7) (see
).
Figure 48 DXi6902 Ethernet
Cabling - Optional 4 x 1 GbE
Ports
Figure 49 DXi6902 Ethernet
Cabling - Optional 2 x 10 GbE
Ports
4
Install the protective bezel on the front of the DXi6902 Node. The bezel snaps into
place on the front of the Node to prevent the removal of the system from the rack
(see
).
a
If you have not already done so, remove the bezel key secured with tape inside
the bezel.
b
Insert the right side of the bezel into the slots on the right side of the Node or
Expansion module.
c
Snap the left side of the bezel into place.
Note:
To remove the bezel, lift the latch on the left side of the bezel.
System Node (Rear)
To 1 GbE Network
System Node (Rear)
To 10 GbE Network