BMC
F
AN
S
PEED
M
ONITORING
3-67
[3.2.580] Fan Speed Monitoring
[3.2.581]
The fan speed thresholds are included in the following
table.
[3.2.583] Processor Error Detec-
tion
[3.2.584] Thermal Trip / Processor
Hot
[3.2.585]
Thermal Trip and Processor Hot can be detected by
GPIO. When an error is detected, the event will be added to
SEL.
[3.2.586]
[3.2.587] Watchdog
[3.2.588]
For the BIOS and OS Agent watchdog, this system
adopts a standard design as specified IPMI 1.5.
[3.2.589] Pre-Timeout Interrupt
Support
[3.2.590]
For the watchdog pre-timeout's interrupt, BMC sup-
ports SMI and NMI. SMI is used in BIOS implementation
[3.2.582] Fan Speed Monitoring
R
OTATIO
N
(
RPM
)
S
ENSOR
N
UMBER
LCT
LNCT
UNCT
UCT
R
EADING
A
VAILABLE
FAN_SY
S1
0x38
480
1040
N/A
N/A
DA
FAN_SY
S2
0x39
480
1040
N/A
N/A
DA
FAN_SY
S3
0x3A
480
1040
N/A
N/A
DA
FAN_SY
S4
0x3B
480
1040
N/A
N/A
DA
FAN_SY
S5
0x3C
480
1040
N/A
N/A
DA
FAN_SY
S6
0x3D
480
1040
N/A
N/A
DA
FAN_SY
S7
0x3E
500
1040
N/A
N/A
DA
FAN_SY
S8
0x3F
500
1040
N/A
N/A
DA
Summary of Contents for W Mainboard Series S210-MBT2W
Page 25: ... 1 0 1 About the Server Chapter 1 ...
Page 31: ... 1 3 31 Functional Architecture ...
Page 121: ... 2 0 1 BIOS Chapter 2 ...
Page 187: ... 3 0 1 BMC Chapter 3 ...
Page 265: ... 4 0 1 Jumpers and Connectors Chapter 4 ...
Page 270: ... 5 0 1 Troubleshooting Chapter 5 ...
Page 275: ... 6 0 1 Installation and Assembly Safety Instructions Chapter 6 ...
Page 280: ... 7 0 1 Safety Information Chapter 7 ...
Page 289: ... 8 0 1 Regulatory and Compliance Information Chapter 8 ...