A
BOUT
THE
S
ERVER
GPIO L
IST
1-61
15
K38
OC7_N_GPIO14
I
P3V3_AUX
PU
"In Suspend Power Well.
Muxed with OC7#.
Defaults to OC7#. If not
used, require a weak pull-
up (8.2kohm to 10kohm) to
Vcc3_3"
OC7_N
(GPI)
GPI
PU_USB_
OC7_N
high
pull up
P3V3_A
UX via
10Kohm
and con-
nect to
FM_ERR
2_N via
0ohm
(EMPTY)
resistor
P3V3
_AUX
16
E30
GPIO15
O
P3V3_AUX
NA
"In Suspend Power Well.
Unmuxed. Defaults to
GPO. "
GPIO15
(GPO)
GPO
FM_SSB_
SAS_SAT
A_RAID_K
EY
N/A
connect
to pin 3
of JP3
(RAID
Key con-
nector)
via
33.2ohm,
pull
2.21k to
P3V3_A
UX
P3V3
_AUX
Upgrad
e KEY
17
H22
SATA4GP_GPIO16
I
P1V1_SSB
PU
"In Main Power Well.
Muxed with SATA4GP.
Defaults to GPI. If not
used, require a weak pull-
up (8.2kohm to 10kohm) to
Vcc3_3"
SATA4GP
(GPI)
GPI
FM_THRO
TTLE_N
high
pull up
P3V3 via
10Kohm,
and con-
nect to
CPU
P3V3
THROT
TLE
18
AV21
TACH0_GPIO17
I
P1V1_SSB
PU
"In Main Power Well.
Muxed with TACH0.
Defaults to GPI. If not
used, require a weak pull-
up (8.2kohm to 10kohm) to
Vcc3_3"
TACH0
(GPI)
GPI
BOARD_S
KU0
high
PU to
P3V3 via
10K and
PD via
10K (NI)
board
SKU ID
[1.3.195] GPIO List (Continued)
I
TEM
P
IN
#
P
IN
N
AME
IO
TYPE
P
OWER
WELL
PU/PD
V
ENDOR
R
ECOMMENDATIONS
(
REFERENCE
DESIGN
)
A
LTERNATE
FUNCTION
(D
EFAULT
)
U
SED
FUNCTION
NET
NAME
STATE
AFTER
RESET
N
ET
CONNECT
TO
Summary of Contents for W Mainboard Series S210-MBT2W
Page 25: ... 1 0 1 About the Server Chapter 1 ...
Page 31: ... 1 3 31 Functional Architecture ...
Page 121: ... 2 0 1 BIOS Chapter 2 ...
Page 187: ... 3 0 1 BMC Chapter 3 ...
Page 265: ... 4 0 1 Jumpers and Connectors Chapter 4 ...
Page 270: ... 5 0 1 Troubleshooting Chapter 5 ...
Page 275: ... 6 0 1 Installation and Assembly Safety Instructions Chapter 6 ...
Page 280: ... 7 0 1 Safety Information Chapter 7 ...
Page 289: ... 8 0 1 Regulatory and Compliance Information Chapter 8 ...