A
BOUT
THE
S
ERVER
AC P
OWER
S
UPPLIES
(
TO
BE
UPDATED
)
1-85
For 62 mil thick board: FCI 10035388-106LF
For 93 mil thick board: FCI 10035388-102LF
[1.3.251] SmaRT (Smart Ride
Through) Definition
[1.3.252]
A standard system requirement is that a loss of power
for 1 cycle of the AC input (20msec for a 50Hz input) shall not
interrupt the operation of the system. In order to support this,
the power supply has a large bulk capacitor used to supply
power to the system while the AC input is too low. This large
bulk capacitor must support 75% of the power supplies output
rating for 20msec to support most system operating conditions.
[1.3.250] CRPS (Common Redundant Power Supply) Connector
P
IN
N
AME
P
IN
N
AME
A1
GND
B1
GND
A2
GND
B2
GND
A3
GND
B3
GND
A4
GND
B4
GND
A5
GND
B5
GND
A6
GND
B6
GND
A7
GND
B7
GND
A8
GND
B8
GND
A9
GND
B9
GND
A10
+12V
B10
+12V
A11
+12V
B11
+12V
A12
+12V
B12
+12V
A13
+12V
B13
+12V
A14
+12V
B14
+12V
A15
+12V
B15
+12V
A16
+12V
B16
+12V
A17
+12V
B17
+12V
A18
+12V
B18
+12V
A19
PMBus SDA
B19
A0 (SMBus
address)
A20
PMBus SCL
B20
A1 (SMBus
address)
A21
PSON
B21
12V stby
A22
SMBAlert#
B22
Cold Redun-
dancy Bus
A23
Return Sense
B23
12V Load
Share Bus
A24
+12V remote
Sense
B24
No Connect
A25
PWOK
B25
No Connect
[1.3.250] CRPS (Common Redundant Power Supply) Connector
P
IN
N
AME
P
IN
N
AME
Summary of Contents for W Mainboard Series S210-MBT2W
Page 25: ... 1 0 1 About the Server Chapter 1 ...
Page 31: ... 1 3 31 Functional Architecture ...
Page 121: ... 2 0 1 BIOS Chapter 2 ...
Page 187: ... 3 0 1 BMC Chapter 3 ...
Page 265: ... 4 0 1 Jumpers and Connectors Chapter 4 ...
Page 270: ... 5 0 1 Troubleshooting Chapter 5 ...
Page 275: ... 6 0 1 Installation and Assembly Safety Instructions Chapter 6 ...
Page 280: ... 7 0 1 Safety Information Chapter 7 ...
Page 289: ... 8 0 1 Regulatory and Compliance Information Chapter 8 ...