SPECIFICATIONS
Flow Rate Range:
±0.07 to 40 ft/sec (±0.02
to 12 m/sec)
Pipe Size:
½” to 48” (15 to 1200
mm)
Accuracy:
±1% of flow rate from
1.5 to 40 ft/sec, ±0.015
ft/sec below 1.5 ft/sec.
Repeatability and
Linearity: ±0.25%
Displays:
White, backlit matrix -
displays flow rate,
totalizer, relay states,
operating mode and
calibration menu
Calibration:
built-in 5-key calibrator with English, French or Spanish language
selection
Power Input:
100-240VAC, 50/60Hz, 10VA or
Optional 9-32VDC, 10 Watts Maximum
Output:
Isolated 4-20mA (1000 ohm load max.). Can be changed to 0-5VDC in
programming
Data Logger:
128MB Data Storage, 26 million data points
Control Relays:
Qty 2, rated 5 amp 240VAC SPDT, programmable flow alarm and/or
proportional pulse
Enclosure:
Watertight, dust tight NEMA4X (IP 66) polycarbonate with a clear
shatter-proof face
Environmental Conditions:
Relative humidity up to 80%, -23 to 60°C ambient temperature,
maximum 5000 m altitude, pollution degree 4, Installation Category II.
Electrical Surge Protection:
Sensor, 4-20mA output and AC power input
Approximate Shipping Weight:
12 lbs (5.5 kg)
7.4 / 188 mm
"
6.46 / 164 mm
"
10
.9
4
"/
27
8
m
m
10
/2
54
m
m
"
CONDUIT ENTRY
LOCATION
SIDE VIEW
5.12 / 130 mm
"
TTFM 6.1
Greyline