![Pulsar Measurement Greyline TTFM 6.1 Instruction Manual Download Page 48](http://html1.mh-extra.com/html/pulsar-measurement/greyline-ttfm-6-1/greyline-ttfm-6-1_instruction-manual_1625415048.webp)
TTFM 6.1 INSTRUCTION MANUAL
48
1 CROSS INSTALLATION OVERVIEW – SE16B Transducers TMK-B1 Kit (Cont.)
9. Sand the pipe at this position if it needs to be prepped because of scale or rust. After prepped, move the
bracket to this 1 cross mark, and tighten it in place. Apply coupling compound to the transducers and
place them in the brackets:
Tips for installing transducers:
a. Be sure the red knob on the brackets are loosened completely.
b. Put the transducer into the bracket by ensuring the bottom of the transducer and the couplant
does not touch the pipe as you slide it in (hover).
c. With the transducer hovering, tighten the red knob on the bracket until tight. The transducer will
be level with the surface of the pipe, and no coupling will have moved.
Proper coupling compound or tape application: