R44-2080
A-7
Configuration Fie1d
Default Setting
Image Transfer
Image Capture Mode
Send Bar Code Data
Image Data Format
Full
Image Compression Mode
Lossy
JPEG Quality (0-30)
3
Feedback Signaling For Reads and Errors
Beeper Volume
High
No Read Message
Disabled
Good Read Beeper Duration
(0 to 99) x 10ms
15 (150ms)
Good Read LED Duration
(0 to 99) x 10ms
15 (150ms)
General Reading
Pointer/Illuminating LEDs
Pointer
Pointer on during read
Illuminating LEDs
LEDs on during read
Pointer On Prior To Reading
Disabled
Pointer Timeout (0 to 99) x 100ms
5 (500ms)
Image Capture Control
AGC Mode
Apply To All Frames But
First
Invert Image
Disabled
Manual Gain Setting (0 to 80)
0
Manual Exposure Setting (0 to 36)
16