R44-2080
37
Interleaved 2/5
[Default = enabled for I 2/5]. Transmission of I 2/5 sym-
bols may be enabled or disabled (see Figure 24).
Check Character Required
[Default = disabled]. If config-
ured to be required, symbols without a check character
are ignored (not transmitted). If configured to not be
required, symbols with or without a check character are
transmitted.
Send Check Characters
[Default = enabled]. The transmis-
sion of the check character may be enabled or disabled.
Minimum Length (2 to max setting)
[Default = 14]. This option
sets the minimum number of characters in the decoded
symbol. Range is from 2 to maximum length setting.
Maximum Length (min setting to 98)
[Default = 98]. Sets the
maximum number of characters in the decoded symbol.
Edit Format
[Default = %D%]. See page 28 for more infor-
mation.
Figure 24. Interleaved 2 of 5 Settings
NOTE
The default minimum length for this setting (14) is high
because of data security issues. It is recommended that
it only be used without a check character in fixed length
applications. All entered values must be an even number
for I 2/5.
Summary of Contents for Imager 8000
Page 1: ...On Screen Programming and Viewing Guide...
Page 6: ...iv Imager 8000 2D Handheld Reader NOTES...
Page 18: ...12 Imager 8000 2D Handheld Reader Figure 7 Com Port Setup...
Page 68: ...62 Imager 8000 2D Handheld Reader NOTES...
Page 84: ...B 8 Imager 8000 2D Handheld Reader NOTES...
Page 85: ...R44 2080 B 9 NOTES...