SAS / SATA II NAS System
User Manual
61
Cache Mode:
The RAID subsystem supports Write-Through Cache and Write-Back Cache.
Write-Through: the RAID controller acknowledges data has been received when it
reaches the disk drives.
Write-Back: the RAID controller acknowledges data has been received when it
reaches the controller’s cache memory. This provides better performance but requires
a battery module support for the cache memory, or a UPS where the system can be
connected.
Tagged Command Queuing:
When this option is enabled, it enhances the overall system performance under multi-
tasking operating systems by reordering tasks or requests in the command queue of
the RAID system. This function should normally remain enabled.
SAS Port/LUN Base/LUN:
SAS Port
: There are two 3Gbps SAS Host Channels in the RAID subsystem. Select
the SAS port where to map the LUN (Volume Set). Options are:
0
,
1
and
0&1
Cluster
.
0&1 Cluster
will make the LUN visible on both SAS ports.
LUN Base
: T h e b ase LUN number. Each LUN Base supports 8 LUNs.
LUN:
Each Volume Set must be assigned a unique LUN ID number. A SAS Port can
connect up to 128 devices (LUN ID: 0 to 127). Select the LUN ID for the
Volume Set.
Volumes To Be Created:
Use this option to create several Volume Sets with the same
Volume Set attributes. Up to 128 Volume Sets can be created.
Summary of Contents for SN-3163S3H-QX
Page 1: ...SAS SATA II NAS System User Manual Revision 1 1 P N PW0020000000365...
Page 10: ...SAS SATA II NAS System 10 User Manual PART I Hardware Components and RAID Subsystem...
Page 41: ...SAS SATA II NAS System User Manual 41...
Page 42: ...SAS SATA II NAS System 42 User Manual...
Page 43: ...SAS SATA II NAS System User Manual 43...
Page 44: ...SAS SATA II NAS System 44 User Manual...
Page 94: ...SAS SATA II NAS System 94 User Manual PART II proNAS System...
Page 115: ...SAS SATA II NAS System User Manual 115 4 Verify the new LV size...