5.5 System Controls
5.5.1 System Configuration
To set the RAID subsystem system configuration options, click the
System
Configuration
link under the
System Controls
menu. The System
Configurations screen will be shown. Set the desired system option as needed.
System Beeper Setting:
This option is used to Disable or Enable the system’s RAID controller alarm beeper.
Background Task Priority:
The Background Task Priority indicates how much time and system resource the RAID
controller devotes to a background task, such as a rebuild operation. The RAID
subsystem allows user to choose the background task priority (High 80%, Medium 50%,
Low 25%, and Ultra Low 5%) to balance between background task process and
Volume Set access. For high RAID subsystem performance, specify a low value.
JBOD/RAID Configuration:
The RAID subsystem supports JBOD and RAID configuration.
SATA NCQ Support:
NCQ is a command protocol in Serial ATA that can only be implemented on native Serial
ATA hard drives. It allows multiple commands to be outstanding within a drive at the
same time. Drives that support NCQ have an internal queue where outstanding
commands can be dynamically rescheduled or re-ordered, along with the necessary
tracking mechanisms for outstanding and completed portions of the workload. Disabled
or Enable the SATA NCQ function.
Summary of Contents for SN-3163S3H-QX
Page 1: ...SAS SATA II NAS System User Manual Revision 1 1 P N PW0020000000365...
Page 10: ...SAS SATA II NAS System 10 User Manual PART I Hardware Components and RAID Subsystem...
Page 41: ...SAS SATA II NAS System User Manual 41...
Page 42: ...SAS SATA II NAS System 42 User Manual...
Page 43: ...SAS SATA II NAS System User Manual 43...
Page 44: ...SAS SATA II NAS System 44 User Manual...
Page 94: ...SAS SATA II NAS System 94 User Manual PART II proNAS System...
Page 115: ...SAS SATA II NAS System User Manual 115 4 Verify the new LV size...