SAS / SATA II NAS System
User Manual
85
5.6.3 Hardware Monitor
To view the RAID subsystem’s hardware information, click the
Hardware Monitor
link
from the
Information
menu. The Hardware Monitor Information screen appears.
The Hardware Monitor Information provides the temperature, fan speed (chassis fan)
and voltage levels of the RAID subsystem. All items are also unchangeable. When the
threshold values are surpassed, warning messages will be indicated through the LCD,
LED and alarm buzzer.
Item
Warning Condition
Controller Board Temperature
> 70 Celsius
HDD Temperature
> 65 Celsius
Controller Fan Speed
< 1500 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V
Summary of Contents for SN-3163S3H-QX
Page 1: ...SAS SATA II NAS System User Manual Revision 1 1 P N PW0020000000365...
Page 10: ...SAS SATA II NAS System 10 User Manual PART I Hardware Components and RAID Subsystem...
Page 41: ...SAS SATA II NAS System User Manual 41...
Page 42: ...SAS SATA II NAS System 42 User Manual...
Page 43: ...SAS SATA II NAS System User Manual 43...
Page 44: ...SAS SATA II NAS System 44 User Manual...
Page 94: ...SAS SATA II NAS System 94 User Manual PART II proNAS System...
Page 115: ...SAS SATA II NAS System User Manual 115 4 Verify the new LV size...