iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
69
#VD
The number of virtual disks in RAID group.
Status
The status of RAID group.
“Online”
Æ
the RAID group is online.
“Offline”
Æ
the RAID group is offline.
“Rebuild”
Æ
the RAID group is being rebuilt.
“Migrate”
Æ
the RAID group is being migrated.
“Scrubbing”
Æ
the RAID group is being scrubbed.
Health
The health of RAID group.
“Good”
Æ
the RAID group is good.
“Failed”
Æ
the hard drive is failed.
“Degraded”
Æ
the RAID group is not completed. The
reason could be lack of one disk or disk failure.
RAID
The RAID level of the RAID group.
Current
Owner
The owner of the RAID group. The default owner is
controller 1.
Preferred
owner
The preferred owner of the RAID group. The default owner
is controller 1.
RG operations description:
Create
Create a RAID group.
Migrate
Migrate a RAID group. Please refer to next chapter for more
detail.
Activate
Activate a RAID group; it can be executed when RG status
is offline. This is for online roaming purpose.
Deactivate
Deactivate a RAID group; it can be executed when RG
status is online. This is for online roaming purpose.
Parity check
Regenerate parity for the RAID group. It supports RAID 3 /
5 / 6 / 30 / 50 / 60.
Delete
Delete a RAID group.
Set preferred
owner
Set the RG ownership to the other controller.
Set disk
property
Change the disk status of write cache and standby.
Write Cache
options:
“Enabled”
Æ
Enable disk write cache.
“Disabled”
Æ
Disable disk write cache.
Summary of Contents for EP-3164D-GAS3
Page 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Page 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Page 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Page 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Page 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Page 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...